SITU ADU

SITU

Loading image...
Loading image...
Loading image...
Loading image...
Loading image...
Loading image...
Loading image...
Loading image...
Loading image...

Exterior Rendering

$220,000 - $280,000

Studio

1 Bathroom

280 sq. ft.

Project Information

The SITU Ancillary Dwelling Unit is a 280 sq. ft. studio loft with high ceilings that is based on a modular structural frame system developed by WikiHouse. The high precision factory built structural units allow for a high performance airtight enclosure that can be rapidly built and is easy to maintain and adapt. The studio apartment contains a bathroom with shower, a kitchen with dishwasher, induction oven and full fridge, a convertible living room/bedroom with fold-down murphy bed, a mini-split AC system, and a storage loft accessed via ship's ladder.

ADU Type

Detached

Building Shape

Rectangular

Square Footage

280 sq. ft.

Width Maximum dimension of the building exterior

14 ft

Length Maximum dimension of the building exterior

20 ft

Building Height Maximum dimension including apex of any pitched roofs

15 ft

Ceiling Height Living Space

13.5 ft

Ceiling Height Bathroom

7 ft

Ceiling Height Sleeping Space

13.5 ft

Business Information

Business Name

SITU

Business Designation

Not Applicable

Business Location

BrooklynNY

Email

design@situ.nyc

Phone Number

 718 855 2170

Registered Design Professional (RDP)

Michael Jerome Brotherton (Story Architecture PLLC)

Email of Registered Design Professional

Not Applicable

Phone Number of Registered Design Professional

Not Applicable

Estimated Cost

Estimates should be rounded to the nearest $10,000 and include building construction, architecture blueprints, engineering blueprints (if applicable), contractor coordination, and city coordination. This estimate does not include costs associated with establishing site connections or any anticipated site specific costs.

What is the current lowest total estimated construction cost of the ADU?

$220000

What is the current highest total estimated construction cost of the ADU?

$280000

Project Components

Appliances

Dishwasher

Refrigerator

Construction Type

Pre-fabricated

Architectural Features

Not Applicable

Style

Contemporary

Material and Finishes

Primary Structural System Material

Not Applicable

Facade Material

Wood

Kitchen Flooring

Wood

Bathroom Flooring

Tile

General Flooring

Wood

Certifications

Industry certifications such as LEED certification, Passive House Certification, and a Zero Energy Ready Home (ZERH) are acquired after building construction. By checking the boxes below, the applicant certifies to the best of their knowledge that the submitted design is compatible with the following standards:

LEED v4.1 Residential: Single Family Certification

No

Passive House Certification

No

Zero Energy Ready Home (ZERH)

No

ENERGY STAR (75 or higher on EPA's 1–100 scale)

No

Other

No

Accessibility

Is the ADU designed with architectural barriers such as steps at the entrance or between rooms?

No

Is the ADU designed with assistive railings (grab bars) installed in the bathroom?

No

Is the ADU designed to accommodate a wheelchair users?

No

Sustainability Features and Certifications

Criteria for energy efficient mechanical systems, building envelope, material sourcing, and material circularity are met when the ADU design exceeds sustainability standards established by New York City, federal agency, and industry standards.

For sustainable design practices, please refer to existing city guidelines and standards such as:

  • HPD Design Guidelines for New Construction
  • New York City, Environmentally Preferable Purchasing (EPP), Minimum Standards for Construction
  • Clean and Circular: Design and Construction Guidelines (NYCEDC)

Mechanical Systems and Building Envelope

Is the ADU designed to incorporate a heat pump that operates with higher-than-minimum equipment efficiencies according to HPDs Electric Heating Policy?

Yes

Is the ADU designed to incorporate drain-water or wastewater heat recovery?

No

Does the ADUs insulation exceed the minimum requirements for New York City Energy Conservation Code (NYCECC)?

Yes

Is the ADU designed to harvest, treat, and reuse greywater to meet a portion of the project’s non-potable water needs?

No

Is the ADU designed with windows with a U-Factor of ≤ 0.27?

Not Applicable

Is the ADU designed with windows with a Solar Heat Gain Efficient (SHGC) of ≤ 0.4?

Yes

What is the Window to Wall Ratio (WWR) of the ADU?

12 %

Material Sourcing and Circularity

Is the ADU design specified to use building materials or products have been extracted, harvested or recovered, as well as manufactured within a 500-mile radius of the project site?

Yes

If the ADU is designed to use wood as a construction material, is it designed to use wood from a sustainable forest?

Yes

If the ADU is designed to use concrete as a construction material, is it designed to use low-carbon concrete?

Not Applicable

If the ADU is designed to use steel as a construction material, is it designed to use recycled steel and/or steel from electric arc furnaces (EAFs)?

Not Applicable

Information provided on this site is for educational purposes only and may not reflect current laws or policies. Always verify details with the NYC Department of Buildings or other New York City agencies before proceeding.

No guarantees of eligibility or approval are made.